Hand Waveguide Switch Parts
Product List
【FEATURES】 |
【APPLICATIONS】 |
※ Low VSWR |
※ Communication System |
※ Low IL |
※ Radar System |
※ High Isolation |
|
【PRODUCT TYPE】
Code |
Description |
Code |
Description |
WES |
E-plane Rectangular Waveguide Hand Switch |
DRWES |
E-plane Double-ridged Waveguide Hand Switch |
WHS |
H-plane Rectangular Waveguide Hand Switch |
DRWHS |
H-plane Double-ridged Waveguide Hand Switch |
WESMD |
E-plane Rectangular Waveguide Electric Switch |
DRWESMD |
E-plane Double-ridged Waveguide Electric Switch |
WHSMD |
H-plane Rectangular Waveguide Electric Switch |
DRWHSMD |
H-plane Double-ridged Waveguide Electric Switch |
Flange Type for Standard
Rectangular Waveguide Coaxial Adapter:
Waveguide Type |
P |
M |
E |
U |
BJ32 ~ BJ70 |
FDP |
FDM |
/ |
/ |
BJ84 ~ BJ320 |
FBP |
FBM |
FBE |
/ |
BJ400 ~ BJ900 |
/ |
/ |
|
FUGP |
Material: A=Aluminum B=Brass C=Copper
【DATA SHEET】
Model No. |
Frequency Range (GHz) |
VSWR (Max.) |
IL (dB) |
Isolation (dB) |
Waveguide |
Flange |
Material |
|
International Standard |
EIA |
|||||||
HI-32WES |
2.60-3.95 |
1.15 |
0.3 |
40 |
BJ32 |
WR284 |
FDP/FDM |
A/C |
HI-32WHS |
2.60-3.95 |
1.15 |
0.3 |
40 |
BJ32 |
WR284 |
FDP/FDM |
A/C |
HI-40WES |
3.22-4.90 |
1.15 |
0.3 |
40 |
BJ40 |
WR229 |
FDP/FDM |
A/C |
HI-40WHS |
3.22-4.90 |
1.15 |
0.3 |
40 |
BJ40 |
WR229 |
FDP/FDM |
A/C |
HI-48WES |
3.94-5.99 |
1.15 |
0.3 |
40 |
BJ48 |
WR187 |
FDP/FDM |
A/C |
HI-48WHS |
3.94-5.99 |
1.15 |
0.3 |
40 |
BJ48 |
WR187 |
FDP/FDM |
A/C |
HI-58WES |
4.64-7.05 |
1.15 |
0.3 |
40 |
BJ58 |
WR159 |
FDP/FDM |
A/C |
HI-58WHS |
4.64-7.05 |
1.15 |
0.3 |
40 |
BJ58 |
WR159 |
FDP/FDM |
A/C |
HI-70WES |
5.38-8.17 |
1.15 |
0.3 |
40 |
BJ70 |
WR137 |
FDP/FDM |
A/C |
HI-70WHS |
5.38-8.17 |
1.15 |
0.3 |
40 |
BJ70 |
WR137 |
FDP/FDM |
A/C |
HI-84WES |
6.57-9.99 |
1.15 |
0.3 |
40 |
BJ84 |
WR112 |
FBP/FBM/FBE |
A/C |
HI-84WHS |
6.57-9.99 |
1.15 |
0.3 |
40 |
BJ84 |
WR112 |
FBP/FBM/FBE |
A/C |
HI-100WES |
8.20-12.4 |
1.15 |
0.3 |
40 |
BJ100 |
WR90 |
FBP/FBM/FBE |
A/C |
HI-100WHS |
8.20-12.4 |
1.15 |
0.3 |
40 |
BJ100 |
WR90 |
FBP/FBM/FBE |
A/C |
HI-120WES |
9.84-15.0 |
1.15 |
0.3 |
40 |
BJ120 |
WR75 |
FBP/FBM/FBE |
A/C |
HI-120WHS |
9.84-15.0 |
1.15 |
0.3 |
40 |
BJ120 |
WR75 |
FBP/FBM/FBE |
A/C |
HI-140WES |
11.9-18.0 |
1.15 |
0.3 |
40 |
BJ140 |
WR62 |
FBP/FBM/FBE |
A/C |
HI-140WHS |
11.9-18.0 |
1.15 |
0.3 |
40 |
BJ140 |
WR62 |
FBP/FBM/FBE |
A/C |
HI-180WES |
14.5-22.0 |
1.15 |
0.3 |
40 |
BJ180 |
WR51 |
FBP/FBM/FBE |
A/C |
HI-180WHS |
14.5-22.0 |
1.15 |
0.3 |
40 |
BJ180 |
WR51 |
FBP/FBM/FBE |
A/C |
HI-220WES |
17.6-26.7 |
1.15 |
0.3 |
40 |
BJ220 |
WR42 |
FBP/FBM/FBE |
A/C |
HI-220WHS |
17.6-26.7 |
1.15 |
0.3 |
40 |
BJ220 |
WR42 |
FBP/FBM/FBE |
A/C |
HI-260WES |
21.7-33.0 |
1.15 |
0.3 |
40 |
BJ260 |
WR34 |
FBP/FBM/FBE |
A/C |
HI-260WHS |
21.7-33.0 |
1.15 |
0.3 |
40 |
BJ260 |
WR34 |
FBP/FBM/FBE |
A/C |
HI-320WES |
26.3-40.0 |
1.15 |
0.3 |
40 |
BJ320 |
WR28 |
FBP/FBM/FBE |
A/C |
HI-320WHS |
26.3-40.0 |
1.15 |
0.3 |
40 |
BJ320 |
WR28 |
FBP/FBM/FBE |
A/C |
HI-400WES |
32.9-50.1 |
1.15 |
0.3 |
40 |
BJ400 |
WR22 |
FUGP |
C |
HI-400WHS |
32.9-50.1 |
1.15 |
0.3 |
40 |
BJ400 |
WR22 |
FUGP |
C |
HI-500WES |
39.2-59.6 |
1.15 |
0.3 |
40 |
BJ500 |
WR19 |
FUGP |
C |
HI-500WHS |
39.2-59.6 |
1.15 |
0.3 |
40 |
BJ500 |
WR19 |
FUGP |
C |
HI-620WES |
49.8-75.8 |
1.15 |
0.3 |
40 |
BJ620 |
WR14 |
FUGP |
C |
HI-620WHS |
49.8-75.8 |
1.15 |
0.3 |
40 |
BJ620 |
WR14 |
FUGP |
C |
HI-740WES |
60.5-91.9 |
1.15 |
0.3 |
40 |
BJ740 |
WR12 |
FUGP |
C |
HI-740WHS |
60.5-91.9 |
1.15 |
0.3 |
40 |
BJ740 |
WR12 |
FUGP |
C |
HI-900WES |
73.8-112 |
1.15 |
0.3 |
40 |
BJ900 |
WR10 |
FUGP |
C |
HI-900WHS |
73.8-112 |
1.15 |
0.3 |
40 |
BJ900 |
WR10 |
FUGP |
C |
Electric
Waveguide Switch
Model No. |
Frequency Range (GHz) |
VSWR (Max.) |
IL (dB) |
Isolation(dB) |
Shift Time (ms) |
Waveguide Type |
Flange |
Material |
|
International Standard |
EIA |
||||||||
HI-32WESMD |
2.60-3.95 |
1.15 |
0.3 |
40 |
≤300 |
BJ32 |
WR284 |
FDP/FDM |
A/C |
HI-32WHSMD |
2.60-3.95 |
1.15 |
0.3 |
40 |
≤300 |
BJ32 |
WR284 |
FDP/FDM |
A/C |
HI-40WESMD |
3.22-4.90 |
1.15 |
0.3 |
40 |
≤300 |
BJ40 |
WR229 |
FDP/FDM |
A/C |
HI-40WHSMD |
3.22-4.90 |
1.15 |
0.3 |
40 |
≤300 |
BJ40 |
WR229 |
FDP/FDM |
A/C |
HI-48WESMD |
3.94-5.99 |
1.15 |
0.3 |
40 |
≤300 |
BJ48 |
WR187 |
FDP/FDM |
A/C |
HI-48WHSMD |
3.94-5.99 |
1.15 |
0.3 |
40 |
≤300 |
BJ48 |
WR187 |
FDP/FDM |
A/C |
HI-58WESMD |
4.64-7.05 |
1.15 |
0.3 |
40 |
≤300 |
BJ58 |
WR159 |
FDP/FDM |
A/C |
HI-58WHSMD |
4.64-7.05 |
1.15 |
0.3 |
40 |
≤300 |
BJ58 |
WR159 |
FDP/FDM |
A/C |
HI-70WESMD |
5.38-8.17 |
1.15 |
0.3 |
40 |
≤300 |
BJ70 |
WR137 |
FDP/FDM |
A/C |
HI-70WHSMD |
5.38-8.17 |
1.15 |
0.3 |
40 |
≤300 |
BJ70 |
WR137 |
FDP/FDM |
A/C |
HI-84WESMD |
6.57-9.99 |
1.15 |
0.3 |
40 |
≤300 |
BJ84 |
WR112 |
FBP/FBM/FBE |
A/C |
HI-84WHSMD |
6.57-9.99 |
1.15 |
0.3 |
40 |
≤300 |
BJ84 |
WR112 |
FBP/FBM/FBE |
A/C |
HI-100WESMD |
8.20-12.4 |
1.15 |
0.3 |
40 |
≤300 |
BJ100 |
WR90 |
FBP/FBM/FBE |
A/C |
HI-100WHSMD |
8.20-12.4 |
1.15 |
0.3 |
40 |
≤300 |
BJ100 |
WR90 |
FBP/FBM/FBE |
A/C |
HI-120WESMD |
9.84-15.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ120 |
WR75 |
FBP/FBM/FBE |
A/C |
HI-120WHSMD |
9.84-15.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ120 |
WR75 |
FBP/FBM/FBE |
A/C |
HI-140WESMD |
11.9-18.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ140 |
WR62 |
FBP/FBM/FBE |
A/C |
HI-140WHSMD |
11.9-18.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ140 |
WR62 |
FBP/FBM/FBE |
A/C |
HI-180WESMD |
14.5-22.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ180 |
WR51 |
FBP/FBM/FBE |
A/C |
HI-180WHSMD |
14.5-22.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ180 |
WR51 |
FBP/FBM/FBE |
A/C |
HI-220WESMD |
17.6-26.7 |
1.15 |
0.3 |
40 |
≤300 |
BJ220 |
WR42 |
FBP/FBM/FBE |
A/C |
HI-220WHSMD |
17.6-26.7 |
1.15 |
0.3 |
40 |
≤300 |
BJ220 |
WR42 |
FBP/FBM/FBE |
A/C |
HI-260WESMD |
21.7-33.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ260 |
WR34 |
FBP/FBM/FBE |
A/C |
HI-260WHSMD |
21.7-33.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ260 |
WR34 |
FBP/FBM/FBE |
A/C |
HI-320WESMD |
26.3-40.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ320 |
WR28 |
FBP/FBM/FBE |
A/C |
HI-320WHSMD |
26.3-40.0 |
1.15 |
0.3 |
40 |
≤300 |
BJ320 |
WR28 |
FBP/FBM/FBE |
A/C |
HI-400WESMD |
32.9-50.1 |
1.15 |
0.3 |
40 |
≤300 |
BJ400 |
WR22 |
FUGP |
C |
HI-400WHSMD |
32.9-50.1 |
1.15 |
0.3 |
40 |
≤300 |
BJ400 |
WR22 |
FUGP |
C |
HI-500WESMD |
39.2-59.6 |
1.15 |
0.3 |
40 |
≤300 |
BJ500 |
WR19 |
FUGP |
C |
HI-500WHSMD |
39.2-59.6 |
1.15 |
0.3 |
40 |
≤300 |
BJ500 |
WR19 |
FUGP |
C |
HI-620WESMD |
49.8-75.8 |
1.15 |
0.3 |
40 |
≤300 |
BJ620 |
WR14 |
FUGP |
C |
HI-620WHSMD |
49.8-75.8 |
1.15 |
0.3 |
40 |
≤300 |
BJ620 |
WR14 |
FUGP |
C |
HI-740WESMD |
60.5-91.9 |
1.15 |
0.3 |
40 |
≤300 |
BJ740 |
WR12 |
FUGP |
C |
HI-740WHSMD |
60.5-91.9 |
1.15 |
0.3 |
40 |
≤300 |
BJ740 |
WR12 |
FUGP |
C |
HI-900WESMD |
73.8-112 |
1.15 |
0.3 |
40 |
≤300 |
BJ900 |
WR10 |
FUGP |
C |
HI-900WHSMD |
73.8-112 |
1.15 |
0.3 |
40 |
≤300 |
BJ900 |
WR10 |
FUGP |
C |